Advantages of Voided Slab System

Advantages

System Advantages

How VOLIMAX voided slab outperforms conventional systems — across architecture, structural engineering, and project cost.

Ana Slider 1 e1607609976947Ana Slider 2Ana Slider 3
%25
Lighter than flat slab
%30
Less seismic force
%20–25
Material savings

Technical Comparison — 01

Vs. Flat Slab

Slabs designed with the voided slab system can reduce the weight of the building by up to 25% compared to flat slabs.

CriteriaFlat (Solid) SlabVOLIMAX Voided Slab
Slab self-weight—≈30% lighter
Seismic performance—Same performance, less load
Ground improvement cost—Lower
Foundation cost—More economical
Concrete & steel savings—20–25% savings
Long spans—8m+ spans
Acoustic / thermal performance—Full slab behavior

Technical comparison per TBDY 2018 & TS500 — contact our engineers for details.

Technical Comparison — 02

Vs. Ribbed Slab

Slabs designed with the voided slab system increase the earthquake resistance of the structure by creating a more rigid diaphragm compared to one way ribbed slabs. The design of traditional one way ribbed slabs have been limited by rules and regulations. One way ribbed slabs have beams with a depth of 30-35 cm in only one direction and usually very few shear walls are utilized. Therefore, the main beams, which must meet the horizontal loads and transfer the loads to the vertical elements, are usually insufficient in structures of 5 floors and above due to their maximum depth of 35 cm. Instead, two way ribbed slabs can be constructed. However, in this design, filling the two way ribbed gaps with EPS, hollow brick or aerated concrete, especially in housing projects, should be evaluated carefully.

While EPS fillings can pose a serious fire risk due to gas compression, toxic smoke emission and/or contribution to the fire by dripping, hollow brick/aerated concrete fillings also have a risk of falling during an earthquake.

CriteriaRibbed (One-way Rib) SlabVOLIMAX Voided Slab
Slab self-weight—≈25% lighter
Diaphragm rigidity & seismic performance—Stiffer diaphragm
TBDY 2018 compliance—Code compliant
EPS / infill fire risk—No infill material
Beam requirement—Works flat
Floor height—Lower storey height
Concrete & steel savings—20–25% savings

Technical comparison per TBDY 2018 & TS500 — contact our engineers for details.

Advantages 01

Architectural Advantages

  • Larger span between columns
  • Reduction in slab thickness
  • Gains from floor height
  • Reduction in shear wall dimensions
  • Reduction in number of columns
  • Flat and continuous ceiling
  • Fire resistance
  • Sound insulation
Mimari avantaj 1
Mimari avantaj 2
Mimari avantaj 3

Advantages 02

Structural Advantages

  • Working in two directions (biaxial)
  • Reduction in building self-weight
  • Reduction in displacements
  • Reduction in loads on the foundation
  • Reduction in earthquake impact
Statik 1
Statik 2
Statik 3

Advantages 03

Cost Advantages

  • Casting in situ
  • Shorter construction time
  • Reduction in concrete consumption
  • Reduction in rebar consumption
  • Easy to use
  • Ease of material logistics; less storage space, more efficient transport
Maliyet 1Maliyet 2 1024x575 1Maliyet 3

Contact

Request

Quotation Fill in the form below or call us at +90 216 518 02 55 to contact our experienced engineers to get more information, study your project and get a quotation for voided slab system.

+90 216 518 02 55

Request a quote